HLK-200MQ110S24-1

Input Characteristic

Project Working conditionMin.Typ.Max.Unit

Maximum input current

66V input voltage, full load output----4A
No-load input current

Rated input voltage

----10mA
Input surge voltage (1sec. max.)Out-of-range input will cause permanent damage-0.7--185VDC
Turn-on voltage
----66
Input under-voltage protectionNo-load test, 

Full load testing will provide overcurrent protection in advance

----64
Remote control (CNT)Positive Logic: The power supply turns on when the CNT pin is left floating or connected to 3.5–15V; it turns off when connected to 0–1.2VReference Voltage-VIN
Negative Logic: The power supply turns off when the CNT pin is left floating or connected to 3.5–15V; it turns on when connected to 0–1.2V



Output Characteristic

Project Working conditionMin.Typ.Max.Unit

Output voltage accuracy

Nominal input voltage, ranging from 0% to 100% load--±0.2±1.0%
Linear regulation rate

Full load, input voltage changes from low voltage to high voltage

--±0.1±0.2

Load regulation

Nominal input voltage, ranging from 10% to 100% load

--±0.1±0.2
Transient Recovery Time25% load step change (step rate 1A/50uS)--200250uS
Transient response deviation-5--5
%
Temperature drift coefficientFull load-0.02--+0.02%/℃
Ripple&Noise20MHz bandwidth, external capaciry ≥220μF--150240mVp-p
Adjustable output voltage (TRIM)
-20--+10%
Remote Output Voltage Sensing(Sense)
----105%
Over Temperature ProtectionMaximum surface temperature of product metal substrate105115125
Output overvoltage protection
125--140V
Output overcurrent protection
9
--12.5A
Short Circuit Protection
Intermittent,sustainable,self-recovering


General Characteristic

Project Working conditionMin.Typ.Max.Unit
Isolation VoltageInput-outputTest time 1 min, leakage current <3mA----3000
VDC
Input - ShellTest time 1 min, leakage current<3mA----2100VDC
Output - ShellTest time 1 min, leakage current<3mA----500VDC
Insulation resistanceInput-outputInsulation voltage 500VDC----100
Switching frequency

--250--KHz
Mean time between failures

----150K hours