Products

  1. Home
  2. Products
  3. DC DC Power Module
  4. DC DC 1W
  5. DC-DC isolated power supply IF0505S-1WR3 IF0503S/IF0509S/IF0512S/IF0515S/IF0524S-1WR3 with short circuit protection
  • j

DC-DC isolated power supply IF0505S-1WR3 IF0503S/IF0509S/IF0512S/IF0515S/IF0524S-1WR3 with short circuit protection

  • Visitor
    18
  • Buycount:
  • Price
    $0.69


Product Feature

1. characteristic:Constant voltage input, isolated stabilized voltage single output,1W 

2. Isolation voltage 3000VDC

3. Low no-load power consumption 0.025W(Typ.)

4. Transfer efficiency up to 78%

5. Output short-circuit protection: continuous short circuit protection, automatic recovery 

6. The voltage of the input power supply is relatively stable.(Voltage variation range±10%Vin) 

7. Operating temperature range :-40°C~+85°C 

8. Small SIP package 

9. International standard pin,direct installation of PCB board. 

10. High reliability and long life design,continuous working time MTBF≥3.5 million hours (3500000Hrs)


Enviroment Condition

Project nameQualificationUnitNotes
Working enviroment temperature-40—+85℃
Storage temperture-40—+125 ℃℃
Relative humidity5—95%
Heat dissipation modenatural cooling

Atmospheric pressure80—106 KpaKpa
Ripple & Noise30/80(max)Mvp-p


Input Characteristics

ItemWorking conditionsMin.Typ.Max.Unit
Input current (full load/no load)5VDC Input Series--270/5--/10m'A
12VDC Input Series--107/3--/5
24VDC Input Series--53/1--/2
Reflection ripple current
--15--m'A

5VDC Input Series-0.7--9
12VDC Input Series-0.7--18
24VDC Input Series-0.7--30
Input filter type
Capacitance filter type
Hot plugged
Non-support



Output Characteristics

Project nameWorking and testing conditionMin.Typ.Max.Unit
Output loadload percentage10--100%
Output Voltage AccuracySee Error Envelope Curve----±3.0%
Linear adjustment rateInput voltage variation ±1%----±0.25%
Load adjustment rate10%~100% load--±1±2%
Ripple & NoisePure resistive load, 20HMz bandwidth, peak-to-peak--3080mVp-p
Temperature Drift CoefficientFull load----±0.03%/℃
Output short circuit protectionContinuous short circuit protection, automatic recovery
Notes: Ripple and Noise Test Methods Twisted Pair Test Method


© 2021 Shenzhen Hi-Link Electronic Co., Ltd. All Rights Reserved.

  Ellen